# Instrument Ontology — Flow Algebra

URL: https://kirethresearch.org/booksai-core/ontologies/mathematical-ontologies/measurement-units-ontologies/instrumentation/instrument-ontology.html

FLOW InstrumentOntology {

  DOMAIN:
    Mathematical Ontologies
    -> Measurement & Units Ontologies
    -> Instrumentation
    -> Instrument Ontology

  PURPOSE:
    Represent a measuring instrument as a device used alone or with supplementary devices to perform measurements, including instrument identity, measurand, sensing and transduction principles, input-output relations, range, span, sensitivity, resolution, threshold, linearity, hysteresis, repeatability, accuracy-related specifications, drift, stability, dynamic response, bandwidth, calibration, adjustment, traceability, environmental influences, data acquisition, configuration, diagnostics, maintenance, uncertainty, provenance, and machine-consumable reasoning across analogue, digital and smart measuring instruments.

  ENTITY MeasuringInstrument {
    TYPE: MeasurementSystemDevice

    DEFINITION:
      device_used_for_making_measurements
      alone_or_in_conjunction_with_one_or_more_supplementary_devices

    PROPERTIES:
      has_identifier
      has_measurand_scope
      has_operating_principle
      has_input_output_relation
      has_measuring_range
      has_metrological_characteristics
      has_calibration_state
      has_configuration
      may_have_sensor
      may_have_transducer
      may_have_digital_processing
      may_have_uncertainty_contributions
      has_provenance
  }

  ENTITY InstrumentIdentifier {
    TYPE: PersistentIdentity

    COMPONENTS:
      manufacturer
      model
      serial_number
      asset_identifier
      firmware_version_when_relevant

    RULE:
      physical_instrument_identity MUST be_preserved_across_measurements
  }

  ENTITY InstrumentState {
    TYPE: OperationalState

    POSSIBLE:
      active
      standby
      warming_up
      calibrated
      calibration_due
      out_of_calibration
      overrange
      fault
      maintenance
      retired

    RULE:
      state_at_measurement_time SHOULD be preserved
  }

  INSTRUMENT_CLASS_MODEL {
    possible:
      analogue_instrument
      digital_instrument
      indicating_instrument
      recording_instrument
      integrating_instrument
      totalising_instrument
      sensor_based_instrument
      laboratory_instrument
      field_instrument
      reference_instrument
      portable_instrument
      embedded_instrument
      smart_instrument

    RULE:
      class_labels MAY overlap_and_should_not_be_forced_into_single_exclusive_class
  }

  MEASURAND_MODEL {
    instrument:
      intended_to_measure_declared_quantity_kinds

    examples:
      length
      mass
      temperature
      pressure
      voltage
      current
      frequency
      optical_power
      concentration

    RULE:
      instrument_capability != actual_measurand_of_every_measurement
  }

  INPUT_OUTPUT_MODEL {
    input_quantity:
      X

    indication_or_output:
      Y

    relation:
      Y =
        f(X,state,environment,time)

    inverse:
      X_hat =
        calibration_inverse(Y,...)

    RULE:
      raw_output_and_measured_quantity_value MUST be_distinguished
  }

  OPERATING_PRINCIPLE_MODEL {
    possible:
      mechanical
      electrical
      electromagnetic
      optical
      thermal
      acoustic
      chemical
      electrochemical
      radiation
      quantum
      hybrid

    RULE:
      operating_principle SHOULD link_to_transfer_and_influence_models
  }

  SENSOR_COMPONENT_MODEL {
    sensor:
      directly_affected_by_measurand_carrier

    RULE:
      sensor MAY be_integral_or_external_to_instrument
  }

  TRANSDUCER_COMPONENT_MODEL {
    transducer:
      converts_input_quantity_or_signal_to_output_quantity_or_signal

    RULE:
      instrument_can_contain_multiple_transduction_stages
  }

  INDICATION_MODEL {
    indication:
      quantity_value_or_displayed_signal_provided_by_instrument

    possible:
      pointer_position
      digits
      voltage
      current
      frequency
      count
      digital_code
      software_value

    RULE:
      indication != corrected_measurement_result_in_general
  }

  RANGE_MODEL {
    lower_limit:
      x_min

    upper_limit:
      x_max

    measuring_interval:
      [x_min,x_max]

    span:
      x_max-x_min

    RULE:
      range_setting MUST be preserved_for_multirange_instruments
  }

  AUTORANGE_MODEL {
    instrument:
      automatically_selects_range

    metadata:
      selected_range
      transition_time
      hysteresis_between_ranges

    RULE:
      selected_range SHOULD be_recorded_with_each_measurement_when_it_affects_resolution_or_uncertainty
  }

  OVERLOAD_MODEL {
    input:
      exceeds_rated_or_measuring_range

    effects:
      saturation
      clipping
      damage
      recovery_delay
      altered_calibration

    RULE:
      overload_event MUST be_flagged
  }

  SENSITIVITY_MODEL {
    local:
      S =
        dY/dX

    linear:
      S =
        gain

    RULE:
      sensitivity != resolution
  }

  RESOLUTION_MODEL {
    definition:
      smallest_change_in_input_causing_perceptible_indication_change

    possible_limiters:
      scale_interval
      display_count
      quantisation
      noise
      threshold
      hysteresis

    RULE:
      nominal_and_effective_resolution SHOULD be_distinguished
  }

  THRESHOLD_MODEL {
    threshold:
      minimum_input_change_or_level_causing_detectable_response

    RULE:
      threshold != resolution_in_general
  }

  DEAD_BAND_MODEL {
    input_interval:
      produces_no_detectable_output_change

    RULE:
      dead_band_can_degrade_small_signal_measurement
  }

  LINEARITY_MODEL {
    calibration_curve:
      Y =
        f(X)

    reference_line:
      Y_ref =
        a*X+b

    nonlinearity:
      deviation =
        Y-Y_ref

    RULE:
      nonlinearity_definition_and_reference_line MUST be declared
  }

  OFFSET_MODEL {
    zero_input:
      output_may_not_equal_zero

    offset:
      b

    correction:
      subtract_or_compensate_estimated_offset

    RULE:
      offset_uncertainty MUST be preserved
  }

  GAIN_MODEL {
    scale_factor:
      a

    relation:
      Y =
        a*X+b

    RULE:
      gain_uncertainty_propagates_to_measurement
  }

  HYSTERESIS_MODEL {
    output:
      depends_on_previous_input_path

    metric:
      difference_between_upscale_and_downscale_indications_at_same_input

    RULE:
      input_history MAY be_required_for_precision_interpretation
  }

  REPEATABILITY_MODEL {
    repeated_indications:
      under_repeatability_conditions

    metric:
      standard_deviation_or_other_declared_dispersion

    RULE:
      repeatability != accuracy
  }

  PRECISION_MODEL {
    precision:
      agreement_among_replicate_indications_or_results

    RULE:
      precision != resolution
      and_precision !=_accuracy
  }

  ACCURACY_SPECIFICATION_MODEL {
    manufacturer_specification:
      may_use
        percent_reading
        percent_range
        percent_full_scale
        digits
        counts
        combined_terms

    RULE:
      instrument_accuracy_specification MUST be parsed_as_operational_limit_or_uncertainty_input
      not_universal_numeric_measurement_accuracy
  }

  TRUENESS_MODEL {
    comparison:
      average_indication_vs_reference

    RULE:
      trueness_requires_reference_value
  }

  DRIFT_MODEL {
    time:
      instrument_characteristics_change

    possible:
      zero_drift
      span_drift
      sensitivity_drift

    RULE:
      calibration_interval SHOULD reflect_drift_and_stability
  }

  STABILITY_MODEL {
    characteristic:
      ability_to_maintain_metrological_properties_over_time

    RULE:
      stability_period_and_conditions MUST be declared
  }

  WARMUP_MODEL {
    warmup_time:
      interval_before_declared_performance_is_met

    RULE:
      measurements_before_warmup_complete SHOULD be_flagged_when_performance_can_change
  }

  DYNAMIC_RESPONSE_MODEL {
    input:
      X(t)

    output:
      Y(t)

    transfer:
      H(s)

    characteristics:
      time_constant
      rise_time
      settling_time
      overshoot
      bandwidth
      phase

    RULE:
      static_calibration_alone_is_insufficient_for_dynamic_measurement
  }

  FIRST_ORDER_MODEL {
    equation:
      tau*dY/dt+Y =
        K*X

    parameters:
      time_constant
      static_gain

    RULE:
      first_order_model_requires_declared_validity
  }

  SECOND_ORDER_MODEL {
    parameters:
      natural_frequency
      damping_ratio
      gain

    RULE:
      resonance_and_overshoot MAY affect_dynamic_indication
  }

  BANDWIDTH_MODEL {
    definition:
      frequency_range_meeting_declared_amplitude_or_phase_criterion

    RULE:
      bandwidth_metric MUST be specified
  }

  LATENCY_MODEL {
    latency:
      delay_between_input_event_and_available_output

    RULE:
      latency != sensor_time_constant
  }

  NOISE_MODEL {
    instrument_output_noise:
      stochastic_variation_not_due_to_measurand_change

    possible_sources:
      thermal
      electronic
      quantisation
      mechanical
      optical
      environmental

    RULE:
      noise_bandwidth MUST be preserved
  }

  SNR_MODEL {
    signal_to_noise_ratio:
      signal_metric/noise_metric

    RULE:
      signal_and_noise_metrics MUST use_compatible_definition
  }

  ENVIRONMENTAL_INFLUENCE_MODEL {
    quantities:
      temperature
      humidity
      pressure
      vibration
      electromagnetic_field
      orientation
      supply_voltage

    influence:
      may_change_offset_gain_noise_or_response

    RULE:
      influence_quantities SHOULD be_recorded_when_material
  }

  TEMPERATURE_COEFFICIENT_MODEL {
    generic:
      parameter(T) =
        parameter_ref
        + alpha*(T-T_ref)

    RULE:
      linear_temperature_coefficient_has_limited_valid_range
  }

  POWER_SUPPLY_MODEL {
    supply:
      voltage_current_frequency_or_battery_state

    effects:
      gain
      offset
      noise
      shutdown

    RULE:
      supply_conditions MAY be_part_of_valid_operating_conditions
  }

  CALIBRATION_MODEL {
    reference_inputs:
      X_ref_i

    indications:
      Y_i

    calibration_function:
      X_hat =
        g(Y,environment,state)

    outputs:
      corrections
      coefficients
      covariance
      uncertainty
      validity_range

    RULE:
      calibration_result MUST be_versioned
  }

  CALIBRATION_STATUS_MODEL {
    fields:
      calibration_date
      due_date
      certificate_identifier
      laboratory
      reference_standard
      traceability
      status

    RULE:
      expired_or_invalid_calibration SHOULD trigger_quality_flag
  }

  ADJUSTMENT_MODEL {
    action:
      alter_instrument_response

    RULE:
      adjustment MAY invalidate_previous_calibration
  }

  ZEROING_MODEL {
    action:
      set_or_estimate_zero_response

    RULE:
      zeroing_is_not_full_calibration
  }

  TRACEABILITY_MODEL {
    chain:
      instrument
      -> calibration_reference
      -> higher_reference
      -> SI_or_declared_reference

    RULE:
      uncertainty_at_each_link SHOULD be preserved
  }

  REFERENCE_INSTRUMENT_MODEL {
    role:
      instrument_used_as_reference_or_higher_quality_comparator

    RULE:
      reference_status_requires_documented_calibration_and_uncertainty
  }

  DIGITAL_INSTRUMENT_MODEL {
    components:
      sensor
      analogue_front_end
      ADC
      processor
      display
      communication

    RULE:
      digital_output_may_include_embedded_corrections
  }

  ANALOGUE_INSTRUMENT_MODEL {
    indication:
      continuous_or_quasi_continuous_scale_position

    concerns:
      scale_reading
      parallax
      friction
      hysteresis

    RULE:
      observer_reading_method MAY affect_result
  }

  ADC_MODEL {
    bit_depth:
      N

    ideal_codes:
      2^N

    ideal_step:
      q =
        full_scale_span/2^N
      under_declared_code_convention

    RULE:
      bit_depth != effective_number_of_bits
  }

  ENOB_MODEL {
    effective_number_of_bits:
      derived_from_noise_and_distortion_per_declared_method

    RULE:
      ENOB_method_and_frequency_conditions MUST be preserved
  }

  SAMPLING_MODEL {
    sampling_frequency:
      f_s

    sample_interval:
      T_s =
        1/f_s
      WHEN f_s > 0

    RULE:
      sample_rate_and_integration_time_are_distinct
  }

  FILTER_MODEL {
    digital_or_analogue:
      filtering

    parameters:
      type
      cutoff
      order
      phase
      delay

    RULE:
      filter_configuration MUST be linked_to_measurement_data
  }

  DISPLAY_MODEL {
    display:
      digits
      scale
      units
      annunciators

    RULE:
      displayed_unit_and_prefix MUST be preserved
  }

  RECORDING_MODEL {
    recording_instrument:
      stores_measurement_values_over_time

    REQUIRE:
      timestamp
      sample_rate
      data_format
      storage_precision

    RULE:
      storage_resolution MAY differ_from_display_resolution
  }

  INTEGRATING_INSTRUMENT_MODEL {
    output:
      integral_over_time_or_other_domain

    example:
      energy_meter
      charge_meter

    RULE:
      integrated_quantity != instantaneous_rate_quantity
  }

  TOTALISING_MODEL {
    cumulative:
      sum_or_integral_of_events_or_quantity

    RULE:
      rollover_reset_and_counter_width MUST be preserved
  }

  SMART_INSTRUMENT_MODEL {
    capabilities:
      embedded_calibration
      compensation
      self_test
      diagnostics
      networking
      digital_identity

    RULE:
      firmware_and_configuration_are_part_of_metrological_state
  }

  FIRMWARE_MODEL {
    version:
      affects_algorithms_and_corrections

    RULE:
      firmware_revision SHOULD be_preserved
  }

  SOFTWARE_CONFIGURATION_MODEL {
    parameters:
      range
      filter
      averaging
      units
      calibration_profile
      trigger
      sampling

    RULE:
      configuration_snapshot SHOULD accompany_measurement
  }

  COMMUNICATION_MODEL {
    interfaces:
      serial
      USB
      Ethernet
      wireless
      fieldbus

    concerns:
      scaling
      packet_loss
      timestamp
      channel_identity

    RULE:
      communicated_value MUST retain_quantity_and_unit_semantics
  }

  DIAGNOSTIC_MODEL {
    possible_flags:
      overrange
      underrange
      sensor_fault
      low_battery
      calibration_due
      internal_error
      temperature_out_of_range

    RULE:
      diagnostic_state MUST be retained_with_measurement
  }

  SELF_TEST_MODEL {
    built_in_test:
      verifies_selected_functions

    RULE:
      successful_self_test != proof_of_full_calibration
  }

  MAINTENANCE_MODEL {
    events:
      cleaning
      repair
      component_replacement
      battery_replacement
      firmware_update
      adjustment

    RULE:
      maintenance_event MAY require_recalibration_or_revalidation
  }

  UNCERTAINTY_MODEL {
    instrument_contributions:
      calibration
      resolution
      repeatability
      noise
      drift
      linearity
      hysteresis
      environment
      timing
      digital_conversion

    RULE:
      instrument_uncertainty_contribution_is_part_of_broader_measurement_uncertainty
  }

  SPECIFICATION_MODEL {
    fields:
      range
      resolution
      accuracy_specification
      sensitivity
      bandwidth
      response_time
      drift
      environmental_limits
      power_requirements

    RULE:
      datasheet_specification_conditions MUST be preserved
  }

  VALIDATION_MODEL {
    tests:
      zero
      span
      linearity
      repeatability
      hysteresis
      resolution
      drift
      response_time
      bandwidth
      environmental_influence

    RULE:
      validation_result MUST identify_test_method_and_reference
  }

  METADATA_MODEL {
    fields:
      manufacturer
      model
      serial_number
      asset_id
      sensor_id
      firmware
      calibration_certificate
      configuration
      range
      unit
      timestamp
      operator
      location_when_relevant
      environment
      maintenance_state

    RULE:
      metadata MUST support_traceability_of_measurement_to_instrument_state
  }

  LIFECYCLE_MODEL {
    states:
      procurement
      acceptance_test
      calibration
      service
      maintenance
      recalibration
      retirement

    RULE:
      measurement_validity MAY depend_on_lifecycle_state
  }

  RELATIONSHIPS {
    MeasuringInstrument -> MEASURES -> Measurand
    MeasuringInstrument -> MAY_CONTAIN -> Sensor
    MeasuringInstrument -> MAY_CONTAIN -> Transducer
    MeasuringInstrument -> HAS -> MeasuringRange
    MeasuringInstrument -> HAS -> Resolution
    MeasuringInstrument -> HAS -> Sensitivity
    MeasuringInstrument -> HAS -> CalibrationState
    Calibration -> MAPS -> IndicationToQuantityValue
    ReferenceStandard -> SUPPORTS -> Calibration
    InstrumentState -> QUALIFIES -> Measurement
    InstrumentConfiguration -> QUALIFIES -> Measurement
    InstrumentCharacteristics -> CONTRIBUTE_TO -> MeasurementUncertainty
  }

  SEMANTIC_EQUIVALENCE {
    "measuring instrument" ~= instrument WHEN measurement_context
    "instrument" ~= measuring_instrument WHEN ontology_scope

    instrument != sensor
    instrument != transducer
    instrument != measuring_system
    indication != measurement_result
    sensitivity != resolution
    resolution != accuracy
    calibration != adjustment
    calibration != zeroing
    datasheet_accuracy != metrological_accuracy
    raw_output != calibrated_quantity_value
  }

  CONSTRAINTS {
    instrument_identity_must_be_preserved = true
    measurand_scope_should_be_defined = true
    measuring_range_must_be_defined = true
    operating_principle_should_be_defined = true
    calibration_state_should_be_defined = true
    configuration_should_be_preserved_when_it_affects_measurement = true
    overload_and_diagnostic_states_must_be_flagged = true
    raw_output_and_calibrated_result_must_be_distinguished = true
    firmware_version_should_be_preserved_when_metrologically_relevant = true
    instrument_uncertainty_components_should_be_propagated_to_measurement_result = true
  }

  MEASUREMENT_MODEL {
    RECORD:
      instrument_identifier
      manufacturer
      model
      serial_number
      asset_identifier
      instrument_class
      operating_principle
      measurand
      raw_indication
      raw_unit
      measured_value
      unit
      range      sensitivity
      resolution
      calibration_identifier
      calibration_function
      calibration_date
      calibration_status
      traceability
      configuration
      sampling_rate
      filter
      bandwidth
      timestamp
      time_reference
      environmental_conditions
      firmware_version
      diagnostic_flags
      maintenance_state
      uncertainty
      provenance

    RULE:
      every_measurement_result SHOULD remain_linked_to_specific_instrument_state_and_configuration
  }

  REASONING_RULES {
    IF raw_indication_and_valid_calibration_function_known
      THEN measured_value =
        calibration_function(raw_indication)

    IF linear_response_Y_equals_aX_plus_b
      AND a != 0
      THEN inferred_input =
        (Y-b)/a

    IF output_increment_and_sensitivity_known
      AND sensitivity != 0
      THEN nominal_input_resolution =
        output_increment/abs(sensitivity)

    IF full_scale_span_and_ADC_bits_known
      THEN ideal_quantisation_step =
        full_scale_span/(2^ADC_bits)
      under_declared_code_convention

    IF sampling_frequency > 0
      THEN sampling_interval =
        1/sampling_frequency

    IF first_order_time_constant_known
      THEN predict_dynamic_response
      under_first_order_model

    IF calibration_expired_or_instrument_fault_flag_active
      THEN measurement_quality_flag =
        requires_review

    IF range_exceeded
      THEN mark_overrange
      AND do_not_interpret_saturated_indication_as_normal_measurement

    IF calibration_parameters_have_covariance
      THEN propagate_covariance_to_measured_value_uncertainty

    IF firmware_configuration_or_adjustment_changes
      THEN create_new_instrument_state_version
      AND reassess_calibration_validity
  }

  VALIDATION {
    CHECK instrument_identity
    CHECK manufacturer_model_and_serial
    CHECK instrument_class
    CHECK operating_principle
    CHECK measurand
    CHECK input_output_relation
    CHECK range_and_span
    CHECK overload_status
    CHECK sensitivity
    CHECK resolution
    CHECK threshold_and_dead_band
    CHECK linearity
    CHECK offset_and_gain
    CHECK hysteresis
    CHECK repeatability
    CHECK drift_and_stability
    CHECK dynamic_response
    CHECK bandwidth_and_latency
    CHECK noise_and_SNR
    CHECK environmental_conditions
    CHECK calibration_state
    CHECK adjustment_or_zeroing_history
    CHECK traceability
    CHECK sampling_and_ADC_configuration
    CHECK firmware_and_software_configuration
    CHECK diagnostic_flags
    CHECK maintenance_state
    CHECK uncertainty
    CHECK provenance
  }

  CONFIDENCE {
    definition_confidence: 1.00
    identity_semantics_confidence: 1.00
    calibration_semantics_confidence: 1.00
    range_sensitivity_resolution_confidence: 1.00
    dynamic_response_confidence: 0.99
    digital_instrument_confidence: 0.99
    uncertainty_integration_confidence: 0.99
    lifecycle_context_confidence: 0.99

    RULE:
      confidence decreases when instrument identity, measurand, range,
      calibration, configuration, dynamic characteristics,
      environmental conditions, diagnostics, uncertainty or provenance is missing or ambiguous
  }

  UPDATE_MODEL {
    ON instrument_registration:
      assign_persistent_identifier
      record_manufacturer_model_serial_and_class
      identify_operating_principle
      attach_measurand_scope
      attach_specifications
      establish_lifecycle_and_provenance

    ON new_measurement:
      attach_instrument_identifier
      identify_measurand
      preserve_raw_indication
      attach_range_and_configuration
      verify_calibration_state
      apply_valid_calibration
      attach_timestamp_environment_and_diagnostics
      attach_uncertainty
      preserve_provenance

    ON calibration_revision:
      preserve_previous_calibration
      update_calibration_function_coefficients_and_covariance
      update_certificate_and_traceability
      reassess_affected_measurements
      update_uncertainty

    ON configuration_revision:
      preserve_previous_configuration
      update_range_filter_sampling_units_or_processing
      create_new_configuration_version
      reassess_resolution_bandwidth_and_measurement_equivalence

    ON adjustment_or_maintenance:
      record_event
      preserve_pre_event_state
      update_instrument_state
      determine_recalibration_or_revalidation_requirement

    ON firmware_revision:
      preserve_previous_firmware
      record_new_version
      identify_metrologically_affected_functions
      reassess_calibration_and_processing

    ON semantic_revision:
      preserve_previous_definition
      record_revision
      recompute_FLOW_HASH
  }

  AI_CONSUMPTION {
    canonical_entity: MeasuringInstrument

    interpretation_order:
      identify_instrument_identity
      identify_instrument_class
      identify_measurand
      identify_operating_principle
      identify_sensor_and_transducer_components
      identify_raw_indication
      identify_range_sensitivity_resolution_and_threshold
      identify_static_and_dynamic_response
      identify_noise_and_environmental_influences
      identify_calibration_adjustment_and_traceability
      identify_sampling_ADC_filter_and_timing
      identify_configuration_firmware_and_software
      identify_diagnostics_and_maintenance_state
      identify_uncertainty
      identify_provenance
      validate_instrument_semantics
      infer_measured_quantity

    ambiguity_controls:
      distinguish_instrument_from_sensor
      distinguish_instrument_from_transducer
      distinguish_instrument_from_measuring_system
      distinguish_indication_from_measurement_result
      distinguish_sensitivity_from_resolution
      distinguish_resolution_from_accuracy
      distinguish_calibration_from_adjustment
      distinguish_calibration_from_zeroing
      distinguish_datasheet_accuracy_specification_from_metrological_accuracy
      distinguish_raw_output_from_calibrated_quantity_value
      preserve_identity_measurand_range_configuration_calibration_environment_firmware_state_and_provenance_context
  }

  PROVENANCE {
    ontology_scope:
      mathematical_measurement_units_instrumentation_and_measuring_instrument_semantics

    parent_path:
      Ontologies
      -> Mathematical Ontologies
      -> Measurement & Units Ontologies
      -> Instrumentation
      -> Instrument Ontology

    authorship:
      Mark Higgins
      Sky (Recursive AI)

    site:
      https://kirethresearch.org
  }

  FLOW_HASH {
    INPUTS:
      canonical_entity
      ontology_path
      instrument_class_model
      measurand_model
      input_output_model
      operating_principle_model
      sensor_component_model
      transducer_component_model
      indication_model
      range_model
      autorange_model
      overload_model
      sensitivity_model
      resolution_model
      threshold_model
      dead_band_model
      linearity_model
      offset_model
      gain_model
      hysteresis_model
      repeatability_model
      precision_model
      accuracy_specification_model
      trueness_model
      drift_model
      stability_model
      warmup_model
      dynamic_response_model
      first_order_model
      second_order_model
      bandwidth_model
      latency_model
      noise_model
      SNR_model
      environmental_influence_model
      temperature_coefficient_model
      power_supply_model
      calibration_model
      calibration_status_model
      adjustment_model
      zeroing_model
      traceability_model
      reference_instrument_model
      digital_instrument_model
      analogue_instrument_model
      ADC_model
      ENOB_model
      sampling_model
      filter_model
      display_model
      recording_model
      integrating_instrument_model
      totalising_model
      smart_instrument_model
      firmware_model
      software_configuration_model
      communication_model
      diagnostic_model
      self_test_model
      maintenance_model
      uncertainty_model
      specification_model
      validation_model
      metadata_model
      lifecycle_model
      relationships
      constraints
      measurement_model
      reasoning_rules
      confidence_model
      update_model

    PURPOSE:
      deterministic_semantic_integrity_identifier

    RECOMPUTE_WHEN:
      ontology_definition_changes
      instrument_identity_or_class_changes
      measurand_or_operating_principle_changes
      range_sensitivity_resolution_or_response_changes
      calibration_adjustment_or_traceability_changes
      sampling_ADC_filter_or_timing_changes
      environmental_noise_or_drift_model_changes
      configuration_firmware_or_software_changes
      diagnostics_maintenance_or_lifecycle_changes
      measurement_record_changes
      uncertainty_model_changes
      constraint_model_changes
      reasoning_rule_changes
  }

}

END FLOW