# Blood Pressure Ontology — Flow Algebra
URL: https://kirethresearch.org/booksai-core/ontologies/mathematical-ontologies/measurement-units-ontologies/biological-measurements/blood-pressure-ontology.html
FLOW BloodPressureOntology {
DOMAIN:
Mathematical Ontologies
-> Measurement & Units Ontologies
-> Biological Measurements
-> Blood Pressure Ontology
PURPOSE:
Represent blood pressure as a cardiovascular pressure measurement describing force per unit area exerted by blood within a defined vascular or cardiac location, including systolic, diastolic, mean arterial, pulse and central pressures, invasive and non-invasive measurement, cuff and oscillometric methods, waveform analysis, hydrostatic effects, posture, device calibration, repeated measurements, uncertainty, provenance, and strict distinctions between pressure values, pressure differences, derived indices and interpretation.
ENTITY BloodPressure {
TYPE: BiologicalPressureQuantity
SYMBOL: P_blood
DIMENSION: M*L^-1*T^-2
SI_UNIT: pascal
SI_SYMBOL: Pa
COMMON_CLINICAL_UNIT:
millimetre_of_mercury
SYMBOL: mmHg
DEFINITION:
blood_pressure :=
pressure_of_blood_at_defined_anatomical_location_and_time_or_cardiac_phase
PROPERTIES:
is_pressure_quantity
depends_on_anatomical_site
varies_with_cardiac_cycle
varies_with_time
may_depend_on_posture
may_depend_on measurement_method
may_have_uncertainty
}
ENTITY SystolicBloodPressure {
TYPE: BloodPressure
SYMBOL: SBP
DEFINITION:
maximum_or_method_defined_peak_arterial_pressure
during_cardiac_cycle
}
ENTITY DiastolicBloodPressure {
TYPE: BloodPressure
SYMBOL: DBP
DEFINITION:
minimum_or_method_defined_arterial_pressure
during_cardiac_cycle
}
ENTITY MeanArterialPressure {
TYPE: DerivedOrIntegratedBloodPressureQuantity
SYMBOL: MAP
EXACT_CYCLE_AVERAGE:
MAP =
(1/T_cycle)*integral_cycle(P(t) dt)
}
ENTITY PulsePressure {
TYPE: PressureDifferenceQuantity
SYMBOL: PP
FORM:
PP = SBP - DBP
}
UNIT_SYSTEM {
SI:
pascal
Pa
common:
millimetre_of_mercury
mmHg
conversion:
1 mmHg approximately_equals 133.322 Pa
RULE:
preserve_original_unit_and_normalized_SI_value
}
ANATOMICAL_SITE_MODEL {
possible_sites:
brachial_artery
radial_artery
femoral_artery
aorta
pulmonary_artery
venous_system
cardiac_chamber
RULE:
blood_pressure_value without_measurement_site
MAY be semantically_incomplete
}
CARDIAC_CYCLE_MODEL {
pressure_waveform:
P = P(t)
cycle_features:
systolic_peak
diastolic_minimum
mean_pressure
pulse_pressure
waveform_shape
RULE:
systolic_diastolic_and_mean_pressures
MUST be represented_as_distinct_quantities
}
PULSE_PRESSURE_MODEL {
PP = SBP - DBP
REQUIRE:
SBP_and_DBP_from_compatible_site_and_measurement_context
RULE:
pulse_pressure_is_pressure_difference
and_not_equivalent_to_systolic_or_diastolic_pressure
}
MEAN_ARTERIAL_PRESSURE_MODEL {
exact:
MAP =
integral_cycle(P(t) dt)/T_cycle
common_approximation:
MAP approximately_equals
DBP + (SBP-DBP)/3
alternative_form:
MAP approximately_equals
(SBP + 2*DBP)/3
CONDITIONS:
approximation_is_context_dependent
and_more_suitable_under_typical_resting_waveform_conditions
RULE:
approximate_MAP_formula MUST_NOT replace_waveform_integral_when_high_accuracy_or_unusual_waveform_context
}
PRESSURE_DIFFERENCE_MODEL {
perfusion_pressure:
pressure_upstream - pressure_downstream
generic:
delta_P = P_1 - P_2
RULE:
absolute_or_gauge_pressure_and_pressure_difference
MUST be distinguished
}
HYDROSTATIC_MODEL {
pressure_difference:
delta_P =
rho*g*delta_h
PARAMETERS:
rho = blood_density
g = gravitational_acceleration
delta_h = vertical_height_difference
RULE:
measurement_height_relative_to_reference_level
SHOULD be preserved_for_precision_measurement
}
CUFF_MEASUREMENT_MODEL {
components:
inflatable_cuff
pressure_sensor_or_manometer
artery
inflation_deflation_protocol
REQUIRE:
cuff_location
cuff_size
limb_position
inflation_pressure
deflation_rate_or_algorithm
RULE:
cuff_dimensions_and_application MAY materially_affect_measurement
}
AUSCULTATORY_MODEL {
method:
cuff_pressure_plus_Korotkoff_sounds
systolic:
associated_with_declared_first_sound_criterion
diastolic:
associated_with_declared_sound_disappearance_or_other_protocol_criterion
REQUIRE:
cuff
stethoscope_or_sensor
deflation_protocol
observer_or_algorithm
RULE:
auscultatory_SBP_and_DBP_are_method_defined_estimates_of_arterial_pressure
}
OSCILLOMETRIC_MODEL {
method:
measure_cuff_pressure_oscillations_during_inflation_or_deflation
directly_observed:
cuff_pressure_oscillation_envelope
derived:
MAP_estimate
SBP_estimate
DBP_estimate
RULE:
oscillometric_SBP_and_DBP_depend_on_device_algorithm
and_raw_cuff_oscillations_are_not_directly_SBP_or_DBP
}
INVASIVE_MODEL {
system:
intravascular_catheter
fluid_filled_or_tip_pressure_sensor
transducer
acquisition_system
measured:
pressure_waveform
REQUIRE:
zero_reference
transducer_level
dynamic_response
damping
calibration
RULE:
invasive_waveform_quality depends_on_transducer_system_response
}
TRANSDUCER_ZERO_MODEL {
zero_reference:
atmospheric_or_declared_reference_pressure
level_reference:
anatomical_reference_height
zero_error:
additive_pressure_offset
RULE:
transducer_zero_and_level MUST be verified_before_interpreting_invasive_pressure
}
DYNAMIC_RESPONSE_MODEL {
characteristics:
natural_frequency
damping
resonance
tubing_compliance
air_bubbles
possible_errors:
overshoot
undershoot
waveform_damping
distorted_systolic_and_diastolic_values
RULE:
dynamic_response SHOULD be considered_for_waveform_derived_pressure
}
POSTURE_MODEL {
possible_postures:
supine
seated
standing
effects:
hydrostatic_pressure
autonomic_response
vascular_distribution
RULE:
posture_and_limb_position SHOULD be preserved
}
REPEATED_MEASUREMENT_MODEL {
readings:
P_1, P_2, ..., P_n
arithmetic_mean:
P_mean =
sum(P_i)/n
REQUIRE:
comparable_method
same_or_declared_site
time_spacing
rest_or_activity_context
RULE:
averaging_protocol SHOULD be declared
}
CONTINUOUS_MONITORING_MODEL {
pressure_series:
P(t)
derived:
beat_to_beat_SBP
beat_to_beat_DBP
MAP
pulse_pressure
variability
RULE:
continuous_pressure_series_and_single_cuff_reading
are_different_measurement_contexts
}
WAVEFORM_MODEL {
features:
systolic_upstroke
systolic_peak
dicrotic_notch
diastolic_decay
derived_quantities:
cycle_mean
pulse_pressure
timing_features
pressure_variability
RULE:
waveform_feature_definition MUST be preserved
}
SIGNAL_QUALITY_MODEL {
possible_issues:
motion
arrhythmia
poor_cuff_fit
weak_pulse
sensor_noise
transducer_damping
calibration_drift
talking_or_movement_during_measurement
RULE:
poor_signal_or_protocol_quality SHOULD reduce_measurement_confidence
}
TEMPORAL_CONTEXT_MODEL {
context:
timestamp
measurement_duration
resting_state
activity
sleep
posture
recent_exertion
environmental_conditions
RULE:
blood_pressure_is_dynamic_and_temporal_context SHOULD be preserved
}
RELATIONSHIPS {
BloodPressure -> IS_A -> PressureQuantity
SystolicBloodPressure -> PHASE_COMPONENT_OF -> ArterialPressureWaveform
DiastolicBloodPressure -> PHASE_COMPONENT_OF -> ArterialPressureWaveform
MeanArterialPressure -> TIME_AVERAGE_OF -> PressureWaveform
PulsePressure -> DIFFERENCE_OF -> SystolicAndDiastolicPressure
HydrostaticHeight -> MAY_SHIFT -> MeasuredPressure
CuffPressure -> ENABLES -> NonInvasiveBloodPressureEstimation
OscillometricSignal -> MAPS_TO -> EstimatedBloodPressure
InvasiveTransducer -> MEASURES -> PressureWaveform
Posture -> QUALIFIES -> BloodPressureMeasurement
SignalQuality -> QUALIFIES -> MeasurementConfidence
}
SEMANTIC_EQUIVALENCE {
"blood pressure" ~= vascular_or_cardiac_pressure_when_site_defined
"SBP" ~= systolic_blood_pressure
"DBP" ~= diastolic_blood_pressure
"MAP" ~= mean_arterial_pressure
"PP" ~= pulse_pressure
systolic_pressure != diastolic_pressure
mean_arterial_pressure != arithmetic_mean_of_SBP_and_DBP_in_general
pulse_pressure != mean_arterial_pressure
cuff_pressure != arterial_pressure
oscillometric_signal != blood_pressure_value
pressure_waveform != single_pressure_summary
}
CONSTRAINTS {
blood_pressure_dimension = M*L^-1*T^-2
anatomical_site_should_be_defined = true
measurement_method_should_be_defined = true
systolic_diastolic_mean_and_pulse_pressure_are_distinct = true
pulse_pressure_requires_compatible_SBP_and_DBP = true
approximate_MAP_formula_requires_declared_context = true
cuff_measurement_requires_cuff_and_limb_context = true
invasive_measurement_requires_zero_and_level_reference = true
posture_and_temporal_context_should_be_preserved = true
uncertainty_and_signal_quality_should_be_preserved = true
}
MEASUREMENT_MODEL {
OBSERVABLE_OR_INFERRED:
SystolicBloodPressure
DiastolicBloodPressure
MeanArterialPressure
PulsePressure
PressureWaveform
COMMON_METHODS:
auscultatory_cuff
oscillometric_cuff
invasive_arterial_catheter
continuous_noninvasive_pressure_monitor
tonometry
waveform_based_device
RECORD:
quantity_type
numerical_value
unit
anatomical_site
laterality_when_relevant
method
device
cuff_size_when_relevant
cuff_position
limb_position
posture
zero_reference_when_invasive
transducer_level
waveform_sampling_rate
signal_quality
timestamp
activity_or_rest_context
repeated_measurement_protocol
calibration_state
uncertainty
provenance
UNCERTAINTY:
measured_or_inferred_blood_pressure = best_estimate +/- uncertainty
}
CALIBRATION_MODEL {
cuff_device:
pressure_sensor_calibration
invasive_system:
transducer_calibration_and_zeroing
reference:
traceable_pressure_standard_when_available
REQUIRE:
calibration_status
valid_pressure_range
calibration_date_or_verification
uncertainty
RULE:
calibration_state MUST match_measurement_device
}
UNCERTAINTY_MODEL {
sources:
pressure_sensor_calibration
cuff_size
cuff_position
limb_position
observer
oscillometric_algorithm
motion
arrhythmia
hydrostatic_height
transducer_zero
dynamic_response
repeated_measurement_variability
temporal_variability
PROPAGATION:
blood_pressure_uncertainty
<- sensor_protocol_geometry_signal_and_temporal_uncertainties
}
REASONING_RULES {
IF systolic_and_diastolic_pressures_known
AND compatible_context
THEN pulse_pressure =
systolic_pressure-diastolic_pressure
IF systolic_and_diastolic_pressures_known
AND typical_resting_waveform_approximation_valid
THEN approximate_MAP =
diastolic_pressure
+ (systolic_pressure-diastolic_pressure)/3
IF full_pressure_waveform_and_cycle_duration_known
AND cycle_duration > 0
THEN MAP =
integral_cycle(pressure dt)/cycle_duration
IF pressure_measurement_height_changes
AND density_gravity_height_difference_known
THEN hydrostatic_pressure_correction =
density*gravity*height_difference
IF repeated_compatible_measurements_known
THEN compute_mean_variability_and_uncertainty
using_declared_protocol
IF raw_oscillometric_signal_known
THEN derive_pressure_values_only_through_validated_device_algorithm
IF invasive_pressure_waveform_known
THEN validate_zero_level_and_dynamic_response
BEFORE waveform_feature_inference
}
VALIDATION {
CHECK quantity_type
CHECK pressure_unit
CHECK anatomical_site
CHECK laterality_when_relevant
CHECK measurement_method
CHECK systolic_vs_diastolic_vs_MAP_vs_pulse_pressure
CHECK compatible_context_for_derived_quantities
CHECK MAP_exact_vs_approximate
CHECK cuff_size_and_position
CHECK posture_and_limb_position
CHECK invasive_zero_and_level
CHECK dynamic_response
CHECK oscillometric_algorithm_context
CHECK repeated_measurement_protocol
CHECK signal_quality
CHECK calibration_state
CHECK uncertainty_representation
}
CONFIDENCE {
definition_confidence: 1.00
dimensional_confidence: 1.00
pulse_pressure_relationship_confidence: 1.00
waveform_MAP_relationship_confidence: 1.00
approximate_MAP_confidence: 0.95
cuff_measurement_context_confidence: 0.97
invasive_measurement_context_confidence: 0.98
RULE:
confidence decreases when anatomical site, method, cuff context,
posture, transducer reference, waveform quality,
calibration or uncertainty is missing or ambiguous
}
UPDATE_MODEL {
ON new_measurement:
identify_pressure_quantity
validate_unit
identify_anatomical_site
identify_method_and_device
attach_cuff_or_transducer_context
attach_posture_and_limb_position
attach_timestamp_and_activity_context
attach_signal_quality
normalize_to_canonical_pressure_unit_when_requested
preserve_original_value_and_unit
compute_derived_pressure_quantities_when_valid
attach_uncertainty
update_blood_pressure_state
ON repeated_measurement:
preserve_each_raw_reading
check_method_site_and_posture_compatibility
update_average_and_variability
preserve_measurement_timing
ON waveform_update:
preserve_raw_waveform
identify_cardiac_cycles
recompute_SBP_DBP_MAP_and_PP
attach_sampling_and_signal_quality
update_uncertainty
ON calibration_revision:
preserve_previous_calibration
recompute_affected_pressure_values
update_uncertainty
update_confidence
ON posture_or_reference_height_change:
preserve_previous_context
update_hydrostatic_reference
avoid_direct_comparison_without_correction_when_material
ON semantic_revision:
preserve_previous_definition
record_revision
recompute_FLOW_HASH
}
AI_CONSUMPTION {
canonical_entity: BloodPressure
canonical_dimension: M*L^-1*T^-2
canonical_SI_unit: Pa
common_unit: mmHg
interpretation_order:
identify_pressure_quantity
identify_value
identify_unit
identify_anatomical_site
identify_systolic_diastolic_mean_pulse_or_waveform
identify_measurement_method
identify_cuff_or_invasive_context
identify_posture_limb_position_and_reference_height
identify_timestamp_and_activity_state
identify_repeated_or_continuous_measurement
identify_signal_quality
identify_calibration
identify_uncertainty
normalize_units
validate_derived_relationships
infer_pressure_relationships
ambiguity_controls:
distinguish_systolic_from_diastolic_pressure
distinguish_MAP_from_simple_arithmetic_mean
distinguish_pulse_pressure_from_MAP
distinguish_cuff_pressure_from_arterial_pressure
distinguish_raw_oscillometric_signal_from_derived_pressure
distinguish_pressure_waveform_from_single_summary_value
distinguish_measurement_from_interpretation
preserve_site_method_posture_reference_signal_quality_and_temporal_context
}
PROVENANCE {
ontology_scope:
mathematical_measurement_and_biological_blood_pressure_semantics
parent_path:
Ontologies
-> Mathematical Ontologies
-> Measurement & Units Ontologies
-> Biological Measurements
-> Blood Pressure Ontology
authorship:
Mark Higgins
Sky (Recursive AI)
site:
https://kirethresearch.org
}
FLOW_HASH {
INPUTS:
canonical_entity
ontology_path
anatomical_site_model
cardiac_cycle_model
pulse_pressure_model
mean_arterial_pressure_model
pressure_difference_model
hydrostatic_model
cuff_measurement_model
auscultatory_model
oscillometric_model
invasive_model
transducer_zero_model
dynamic_response_model
posture_model
repeated_measurement_model
continuous_monitoring_model
waveform_model
signal_quality_model
temporal_context_model
relationships
constraints
measurement_model
calibration_model
uncertainty_model
reasoning_rules
confidence_model
update_model
PURPOSE:
deterministic_semantic_integrity_identifier
RECOMPUTE_WHEN:
ontology_definition_changes
pressure_quantity_definition_changes
anatomical_site_model_changes
cuff_or_oscillometric_model_changes
invasive_measurement_model_changes
waveform_or_MAP_model_changes
posture_or_hydrostatic_model_changes
calibration_model_changes
measurement_model_changes
constraint_model_changes
reasoning_rule_changes
unit_model_changes
}
}
END FLOW